- nutrient monitoring in wetland areas for environment control
- sewage treatment plant
- effluent discharge monitoring
- aquaculture


°áÁ¤ÀûÀÎ º¯¼ö(¿¹¸¦ µé¾î ¼öÄ¡°¡ °©ÀÚ±â ¿Ã¶ó°¥ ¶§)°¡ »ý±æ°æ¿ì systemÀº ½ÇÇè½Ç¿¡¼­ ºÐ¼®ÇÒ¼ö ÀÖ´Â ¸¸Å­ÀÇ sampleÀ» ÀÚµ¿À¸·Î µû·Î ÀúÀåÇÑ´Ù. 8°³ÀÇ sensor ¿¹¸¦µé¾î depth, Flow, rainfall, weather conditionµîÀº ÇÑ data·Î ¸ðµÎ ºÐ¼®µÇ¾î ¿Ïº®ÇÑ ÃøÁ¤ systemÀ» Á¦°øÇÑ´Ù.
25Á¤µµÀÇ °³º°ÀûÀÎ Schedule·Î ƯÁ¤ ½Ã°£À̳ª Ưº°ÇÑ Á¶°ÇÀÌ ÀÏ¾î ³¯ °æ¿ì ¶Ç´Â ÀÏÁ¤ÇÑ ¼öÁØÀ» ³Ñ´Â ¿ä¼Ò°¡ °¨ÁöµÉ °æ¿ì Aualab ÀÛµ¿ Çϵµ·Ï ÇÒ ¼ö ÀÖ´Ù. ÀÌ·¯ÇÑ ´É·ÂÀº »ç¿ëÀÚ°¡ field¸¦ ¹æ¹®ÇÏ´Â ½Ã°£°ú ºñ¿ë(½ÇÇè½Ç¿¡¼­ ÃøÁ¤ÇÏ´Â)À» ȹ±âÀûÀ¸·Î ÁÙÀÏ ¼ö ÀÖÀ¸¸ç, »ç¿ëÀÚ´Â ´ÙÀ½ÀÇ °æ¿ì ¾Ë¶÷À» SettingÇÏ¿© »ç¿ëÀÚ¿¡°Ô ¾Ë·Á ÁÙ¼ö ÀÖ´Ù.

- sample measurements outside predetermined levels
- low reagent and standard liquids
- limited memory in the data logger
- low battery charge
- water ingress


AqualabÀº 24½Ã°£ µ¶¸³ÀûÀ¸·Î ÀÛµ¿Çϸç AlarmÅëÇØ ÀÌ»ó ½Ã ¿¹¸¦ µé¾î ¹ø°³°¡ ÃÆÀ» °æ¿ì message¸¦ ÀúÀåÇÏ°í º¸³»ÁØ´Ù. ¶ÇÇÑ Solar PanelÀ» ¼¼¿ö ¿ÜºÎÀü¿ø¾øÀÌ µ¶ÀÚÀûÀ¸·Î ÀÛµ¿ ÇÒ¼öÀÖ´Ù.
ÀÌ Aualab systemÀº dataÅë½ÅÀ» ÇöÀå¿¡¼­´Â ÈÞ´ë¿ë PC¸¦ ÅëÇØ Rs232Æ÷Æ®·Î ÇÏ¸ç ¿ø°ÝÁö´Â ÀüÈ­¼±À̳ª GSM¸ðµ©, À§¼º, Radio ¹æ½ÄÀ¸·Î data¸¦ ¹ÞÀ» ¼ö ÀÖ´Ù.
»ç¿ëÀÚ´Â Smartcom Software¸¦ »ç¿ëÇÏ¿© ¿ø°ÝÀ¸·Î Åë½ÅÀ» Çϸç Aquagraf software¸¦ ÀÌ¿ëÇÏ¿© Ç¥³ª ±×·¡ÇÁµîÀ¸·Î ÀڷḦ »êÃâ ÇÒ ¼öÀÖ´Ù. ¾ð°ÝÁö¿¡¼­ ÀÛµ¿ÇÏ¿© »ç¿ëÀÚÀÇ °£¼·À» ÃÖ¼ÒÈ­Çϰí ÀÛµ¿ÀÚ´Â ¾î¶² ¹®Á¦°¡ ¹ß»ýÇÏ¸é ¿ø°ÝÁö¿¡¼­ hyper Terminal °°Àº ÇÁ·Î±×·¥À¸·Î Àåºñ¿¡ Á¢¼ÓÇÏ¿© ¹®Á¦¸¦ Á¦°Å ÇÒ ¼öÀÖ´Ù.



  AQUALAB_Insert.pdf


-----------------------------------------------------------------------------

Greenspan Technology has manufactured
an automatic
analysis system, based on technology developed by
the CSIRO and other research institutions. Designed to provide water quality analyses in
remote locations and communicate the laboratory
comparable data in near real time, Greenspan
analysers can provide a total solution for on-line
analysis.

The analysers are designed to meet the analysis
requirements of the user and the harsh
environment of remote locations.

...


AQUALAB offers multiple physical and chemical parameters housed in an
environment controlled enclosure. Analysis parameters are housed in
chemistry modules within the analysers, the configurations of the chemistry
modules and analysers are:
--------------------------------------------------------------------------------------------------------------------------
Module Parameter
Physicals - Electrical Conductivity
- pH
- Dissolved Oxygen
- Oxygen Reduction Potential
- Temperature
- Turbidity
   
Nutrients - Nitrate
- Dissolved Reactive Phosphate
- Ammonia/Ammonium
   
TP/TN - Total Phosphorus
- Total Nitrogen
   
TOC - Total Organic Carbon
-------------------------------------------------------------------------------------------------------------------------- The methodologies are the same as those used in standard laboratory
analyses:

--------------------------------------------------------------------------------------------------------------------------
Parameter Sensor Method
pH Glass electrode Standard Method 4500-H+ B
Electrical Conductivity Conductivity cell Standard Method 2520B
Dissolved Oxygen Galvanic membrane electrode Standard Method 4500-O G
Oxygen Reduction Potential Platinum Electrode Standard Method 2580B
Turbidity Nephelometer Standard Method 2130B
Nitrate (NO3) Ion Selective Electrode Standard Method 4500- NO3 D
Dissolved Reactive Phosphate (PO4) Colorimetric Standard Method 4500-P E
Ammonia (NH3) Gas Ion Selective Electrode Standard Method 4500-NH3 E
Ammonium (NH4) Ion Selective Electrode  
Total Phosphorus Colorimetric Standard Method 4500-P E
Total Nitrogen Colorimetric Standard Method 4500-Norg D (Mod)
Total Organic Carbon Nondispersive IR Standard Method 5310 D


--------------------------------------------------------------------------------------------------------------------------